Measuring Range | 0~0.1MPa......200MPa |
Overload capability | 2times full scale |
Burst pressure | 4times full scale |
Accuracy | ±0.1%F.S, ±0.25%F.S, ±0.5%F.S |
Stable | typically 0.25%F.S per year, 0.4%F.S(Max) per year |
Medium temperature range | -50°C~150°C (-50°C~230°C is available on requrest) |
Compensated Temperature | -20°C~120°C |
Medium | Liquids and gases, compatible with stainless steel1Cr18Ni9Ti |
Electrical overview | 2 wire | 3 or 4 wire |
Output | 4~20mA | 0~20mA | 0~10mA | 0~5V | 0~10V |
Power Supply | 12~30Vdc | 12~30Vdc |
Load | (U-10)/0.02 | (U-10)/0.02 | 20k |
Insulation reistance | 100M @50V |
Insulation voltage | 500V@60 second |
Vibration /Constant shock | 10g/5~2000Hz, axes X/Y/Z20g sine 11ms |
Life | 2×106 cycles @25? |
Electrical Connection | DIN43650C, M12 Series, Packard, Cable |
Pressure connection | M20×1.5, G1/4, G1/2, R1/2, NPT1/2, NPT1/4 |
Pressure Type | Guage,Seal Guage, Abosolute |
Electro Magnetic Compatibility | EN50081-1/-2, EN50082-2 |