| Measurement Range | 0~0.2MPa...60MPa |
| Overload Pressure | 1.5 times of full scales |
| Burst Pressure | 3 times of full scales |
| Accuracy | ±0.5%F.S. |
| Long Term Stability | Typical value: 0.25%F.S, Maximum: 0.4%F.S |
| Medium Temperature | -40°C~120°C |
| Compensated Temperature | -10°C~70°C |
| Medium Compatibility | All corrosive medium compatible with 1Cr18Ni9Ti |
| Output Mode | Two- wired | Three-wired |
| Output | 4~20mA | 0~5V | 1~5V | 0.5~4.5V | 0~10V |
| Power Supply | 10~30VDC | 8~30VDC | 5V(ratio) | 11~30VDC |
| Load Resistance | (U-10)/0.02 | ?20k? |
| Insulation | 100M ?@50V |
| Electrical Connection | DIN63650, IP65; GX16-7, IP45; Wire,IP68; |
| Pressure Connection | M20×1.5, G1/4, G1/2, R1/2, NPT1/2 |
| Response Time | 10ms |
| Pressure Form | Gauge pressure, Seal Gauge Pressure |
| Electromagnetic compatibility | Electromagnetic transmit: EN50081-1/-2;electromagnetic sensitivity: EN50082-2 |