Measurement Range | 0~±5kpa……±5000kPa |
Overload Pressure | 1.5 times of full scales |
Static Pressure | 3, 5, 10 times of full scales, 20,Mpa |
Accuracy | ±0.25%F.S, ±0.5%F.S |
Long Term Stability | Typical value: 0.1%F.S, Maximum: 0.2%F.S |
Working Temperature | -40°C~85°C |
Compensated Temperature | -10°C~70°C |
Medium Compatibility | All corrosive medium compatible with 1Cr18Ni9Ti and 316L |
Output Mode | Two- wired | Three-wired |
Output | 4~20mA | 0/1~5V | 0~10V |
Power Supply | 12~30VDC | 8~36VDC/AC | 11~30VDC/AC |
Load Resistance | (U-10)/0.02 | >100k |
Insulation | >100M @50V |
Electrical Strength | 500V @60second |
Impulse Current | 10g/5~2000Hz,axes X/Y/Z20g sine 11ms |
Protection Class | Water resistant wire leads, IP68; DIN43650, cover IP65 | | |
|
Response Time | 10ms |
Pressure Endurance | 2x106pressure circles @25 |
Electromagnetic Compatibility | Electromagnetic transmit: EN50081-1/-2 |
Electromagnetic sensitivity: EN50082-2 |
Lighting-proof | Air conduction voltage 8000v, shell or cable conduction voltage 4000V; can also be provided according to customer’s requirement |