Model | MDR-60-24 |
Output | DC output Voltage | 24V |
Voltage tolerance | ±1.0% |
Rated Current | 2.5A |
Related Power | 60w |
Wave&Noise | 150mVp-p |
Voltage adjust range | 48-56V |
Set up,rise time | 500ms 30ms/230VAC 1000ms,30ms/115VAC at full load |
hold up time | 50ms/230VAC 20ms/115VAC at full load |
Input | Voltage Range | 85 ~ 264VAC 47-63HZ 120-370VDC |
Input Current | 0.55A/115VAC 0.35A/230VAC |
Efficiency | 0.84 |
AC inrush current | Cold start current 35A/115V 70A/230VAC |
Leakage current | <1mA/240VAC |
Protection | Over load | Above 105%-160% rated output power |
hiccup mode, recovery automatically after fault condistion is removed |
Over voltage | 57.6-64.8V |
Shut down o/p voltage, re-power on to recover |
Function | DC OK active single | Relay contact rating(max) :30V/1A resistive |
Environment | Working temp humidity | -20~+70°C 20%~90%RH |
Stor temp, humidity | -20~+85°C 20%~90%RH Non-condensing |
Safety | safety standards | UL508,TUV EN60950-1 approved |
Withstand voltage | I/P-O/P:3KVAC I/P-FG:2KVA O/P-FG:0.5KVA |
Isolation resistance | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25 %RH |
EMC emission | Compliance to EN55011,EN55022,EN61204-3 class B,EN61000-3-2,-3 |
Size | size | 40*90*100mm W*H*D |
Package | 0.45kg |