| Model | MDR-100-24 |
| Output | DC output Voltage | 24V |
| Voltage tolerance | ±1.0% |
| Rated Current | 4.1A |
| Related Power | 100w |
| Wave&Noise | 150mVp-p |
| Voltage adjust range | 48-56V |
| Set up,rise time | 500ms 30ms/230VAC 1000ms,30ms/115VAC at full load |
| hold up time | 50ms/230VAC 20ms/115VAC at full load |
| Input | Voltage Range | 85 ~ 264VAC 47-63HZ 120-370VDC |
| Input Current | 0.55A/115VAC 0.35A/230VAC |
| Efficiency | 0.84 |
| AC inrush current | Cold start current 35A/115V 70A/230VAC |
| Leakage current | <1mA/240VAC |
| Protection | Over load | Above 105%-160% rated output power |
| hiccup mode, recovery automatically after fault condistion is removed |
| Over voltage | 57.6-64.8V |
| Shut down o/p voltage, re-power on to recover |
| Function | DC OK active single | Relay contact rating(max) :30V/1A resistive |
| Environment | Working temp humidity | -20~+70°C 20%~90%RH |
| Stor temp, humidity | -20~+85°C 20%~90%RH Non-condensing |
| Safety | safety standards | UL508,TUV EN60950-1 approved |
| Withstand voltage | I/P-O/P:3KVAC I/P-FG:2KVA O/P-FG:0.5KVA |
| Isolation resistance | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25 %RH |
| EMC emission | Compliance to EN55011,EN55022,EN61204-3 class B,EN61000-3-2,-3 |
| Size | size | 55*90*100mm W*H*D |
| Package | 0.68kg |