SPECIFICATION | ||
---|---|---|
Model | NDR-120-24 | |
Output | DC output Voltage | 24V |
Voltage tolerance | ±1.0% | |
Rated Current | 5A | |
Related Power | 120w | |
Wave&Noise | 150mVp-p | |
Adjustable range for DC Voltage | ±10% | |
Set up,rise time | 800ms 600ms 50ms | |
Input | Voltage Range | 85 ~ 264VAC 47-63HZ 120-370VDC |
Input Current | 1A/115VAC 0.5A/230VAC | |
Efficiency | 0.82 | |
AC inrush current | Cold start current 35A/115V 70A/230VAC | |
Leakage current | <0.5mA/240VAC | |
Protection | Over load | Related output power 105-135% start overload protection |
Protection type: cutoff output, recovery after restart power | ||
Over voltage | 27.6V-32.4V | |
Hiccup mode,recovers automatically after fault condition | ||
Environment | Working temp humidity | -10~+60°C 20%~90%RH |
Stor temp, humidity | -20~+85°C 20%~90%RH Non-condensing | |
Safety | Withstand voltage | I/P-O/P:1.5KVAC 1min |
I/P-FG:1.5KVAC 1min | ||
O/P-FG:0.5KVAC 1min | ||
Standard | Safety standard | Fit UL1012 |
Refer | Design refer to GB4943,UL60950,EN60950 | |
EMC standard | Design refer to GB9254,EN55022 Class A | |
Size | size | 40*W125.5*H113.5mm |
Package | 0.52kg, |