DC output voltage:12V
Rated output current:45A
DC Output power:540W
Model Specification | S-600-12 | S-600-15 | S-600-24 | S-600-36 | S-600-48 |
---|---|---|---|---|---|
DC output voltage | 12V | 15V | 24V | 36V | 48V |
Output voltage range(Note:2) | ±1% | ±1% | ±1% | ±1% | ±1% |
Rated output current | 45A | 40A | 25A | 16.6A | 12.5A |
Output current range(Note:2) | 0-45A | 0-40A | 0-25A | 0-16.6A | 0-12.5A |
Wave and noise(Note:3) | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 240mVp-p |
Inlet stability(Note:4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stability(Note:5) | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
DC Output power | 540W | 600W | 600W | 600W | 600W |
Efficiency | 74% | 78% | 82% | 82% | 83% |
Adjustable range for DC voltage | 10~13.2V | 13.5~18V | 20~26.4V | 33~39V | 41~56V |
AC input voltage range | 90~132VAC/180~264VAC selected by switch 47~63Hz; 254~370VDC | ||||
Input current | 6.5A/115V 4A/230V | ||||
AC Inrush current | 25A/115V 50A/230V | ||||
Leakage current | <3.5mA/240VAC | ||||
Overload protection | 105%~150% Type: Cut off output Reset: auto recovery | ||||
Over-voltage protection | 13.8~16.2V | 15.5~18.2V | 27.6~32.4V | 39~45V | 57.6~67.2 |
High-temperature protection | ERH3>=65℃~70℃Fan on, <=55℃~60℃ Fan off,>=80℃~85℃, Cut off output(5~15V)~(24~48V) |
||||
Temperature coefficient | ±0.03%/℃(0~50℃) | ||||
Setup,rise,hold up time | 200ms, 100ms, 20ms | ||||
Vibration | 10~500Hz, 2G 10min,/1cycle, period for 60min, Each axes | ||||
Withstand voltage | Input and output internal: 1.5KvAC, Input and enclosure: 1.5KvAC, Output and enclosure: 0.5KvAC |
||||
Isolation resistance | Input and output internal: Input and enclosure, Output and enclosure: 500VDC/100MΩ |
||||
Working temperature and humidity | -10℃~+60℃(Refer to output derating curve),20%~90%RH | ||||
Stoerall dimension | -20℃~+85℃,10%~95%RH | ||||
Overall dimension | 240×125×64mm | ||||
weight | 1.25Kgs | ||||
safety standards | Design refer to UL 1950 | ||||
EMC standards | Design refer to FCC Part15 J Part15J class A |