SPECIFICATION | ||
---|---|---|
Model | MS-100-24 | |
OUTPUT | DC VOLTAGE | 24V |
RATED CURRENT | 4.2A | |
CURRENT RANGE | 0 ~ 4.2A | |
RATED POWER | 100.8W | |
RIPPLE&NOISE(Max) | 120mVp-p | |
VOLTAGE ADJ.RANGE | 21.6 ~ 26.4V | |
VOLTAGE TOLERANCE | ±1.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±1.0% | |
SETUP,RISE TIME | 500ms, 20ms/230VAC500ms, 20ms/115VAC(fullload) | |
HOLD UP TIME(Typ.) | 30ms/230VAC 25ms/115VAC(fullload) | |
INPUT | VOLTAGE RANGE | 85 ~ 132VAC/176 ~ 264VDC(by selected switch) or248~373VDC |
FREQUENCY RANGE | 47~63Hz | |
EFFICIENCY(Typ.) | 0.84 | |
AC CURRENT(Typ.) | 2.4A/110VAC 1.2A/230VAC | |
INRUSH CURRENT(Typ.) | 36A/230VAC | |
LEAKAGE CURRENT | <0.75mA / 240VAC | |
PROTECTION | OVER LOAD | 110~ 150% ratedoutputpower |
Protection type : Hiccuo mode,recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 28.8 ~ 33.6V | |
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved | ||
ENVIRONMENT | WORKING TEMP | -10 ~ +60°C (Referto“derating curve” ) |
WORKING HUMIDITY | 20~90%RH non-condensing | |
STORAGETEMP.,HUMIDITY | -20 ~ +85°C, 10 ~ 95% RH | |
TEMP.COEFFICIENT | 0.03%/(0~50) | |
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | |
SAFETY | SAFETY STANDARDS | CE,GB4943.1safety standard |
WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC 1minute I/P-FG:1.5KVAC 1minute O/P-PG:0.5KVAC 1minute | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100MOhms/500VDC | |
EMC EMISSION | EN61000-3-2 2014/EN61000-3-3 2013 | |
EMC IMMUNITY | EN 55032:2015/EN55035:2017/60950-1 | |
OTHERS | MTBF | 327.9K hrs MIL-HDBK-217F(25°C) |
DIMENSION | 159*98*38mm |