LRS-250-12

DC output voltage:12V

Rated output current:20A

DC Output power:250W

Model
Specification
LRS-250-5LRS-250-12LRS-250-15LRS-250-24LRS-250-36LRS-250-48
OutputDC output voltage5V12V15V24V36V48V
Rated output current40A20A116.6A10A7A5A
Output current range(Note:2)0-40A0-20A0-16.6A0-10A0-7A0-5A
DC Output power250W250W250W250W250W250W
Wave and noise(Note:3)150mVP-P150mVP-P150mVP-P150mVP-P200mVP-P200mVP-P
Adjustable range for DC voltage±10%±10%±10%±10%±10%±10%
Voltage accuracy±3%±2%±2%±2%±2%±2%
Inlet stability(Note:4)±1%±1%±1%±1%±1%±1%
Load stability(Note:5)±2%±1%±1%±0.5%±0.5%±0.5%
Setup,rise,hold up time1300ms, 50ms/230VAC,1300ms, 50ms//115VAC(full load)
InputAC input voltage range and frequency90~132VAC/180-264VAC ;47~63Hz;240~370VDC
Efficiency87%1.1%88%1.1%1.1%89%
Input current4A/115VAC;2.2A/230V
AC Inrush currentCole-start current: 30A/115V,60A/230V
Leakage current<2mA/240VAC
ProtectionOverload protection105%~150% Type: Cut off output Reset: auto recovery
Over-voltage protection5.75-6.75V13.8-16.2V18-21V28.8-33.6V41.4-46.8V55.2-64.8V
EnvironmentWorking temperature and humidity-20℃~+70℃(Refer to output derating curve),20%~90%RH
Stoerall dimension……………………
Temperature coefficient±0.03%/℃(0-50℃)
Vibration10~500Hz, 2G 10min,/1cycle, period for 60min, Each axes
Standardssafety standardsMeet UL508,TUVEN60950-1 requirement (Not apply for the mark)
Withstand voltageI/P-O/P:3KVAC,I/P-FG: 2KVAC,O/P-FG:0.5KVAC
Isolation resistanceI/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70% RH
OthersMTBF standards……………………
Overall dimension215X115X30mm(W*H*D)
weight0.68Kgs