Model | |||||
---|---|---|---|---|---|
Specification | Q-100-B | Q-100-D | Q-120-B | Q-120-C | Q-120-D |
DC output voltage | 12V | 24v | 5v | 15v | 12v |
Rated output current | 2A | 2A | 11A | 3.5A | 2A |
Output current range | 0.2-2A | 0.2-2A | 2-12A | 0.5-5A | 0.2-5A |
Wave and noise (Note: 3) | 120mVp-p | 150mVp-p | 80mVp-p | 150mVp-p | 120mVp-p |
Voltage accuracy | ±1% | ±1% | ±2% | ±1% | ±1% |
Inlet stability (Note: 4) | ±1% | ±1% | ±0.5% | ±1% | ±1% |
Load stability (Note: 5) | ±1% | ±1% | ±1% | ±1% | ±1% |
DC Output power | 106W | 106W | 120W | 122.5W | 124W |
Efficiency | 0.76 | 0.76 | 0.77 | 0.76 | 0.8 |
AC input voltage range | 176~264VAC 50~60Hz; | ||||
Input current | 1.5A/230V | 1.25A/230V | |||
AC Inrush current | Cole-start current 2.5A/115V 1.25A/230V | ||||
Leakage current | <0.5mA/240VAC | ||||
Overload proctection | 105%~150% Type: Cut off output Reset: auto recovery | ||||
Over-voltage protection | Short-circuit Over-load Over-heat | ||||
High-temperature protection | IP67 | ||||
Temperature coefficient | ±0.03%/℃(0~50℃) | ||||
Setup, rise, hold up time | 200ms, 100ms, 30ms | ||||
Vibration | 10~500Hz, 2G 10min,/1cycle, period for 60min, Each axes | ||||
Withstand voltage | Input and output internal: 1.5KVAC, Input and enclosure: 1.5KVAC, Output and enclosure: 0.5KVAC | ||||
Isolation resistance | Input and output internal: Input and enclosure, Output and enclosure: 500VDC/100MΩ | ||||
Working temperature and humidity | -30℃-65℃(Refer to output derating curve),20%~90%RH | ||||
Stoerall dimension | -20℃~+85℃,10%~95%RH | ||||
Overall dimension | 199x110x50mm | ||||
Weight | 0.85kgs | ||||
Safety standards | Meet UL 1012 requirement (Not apply for the mark) | ||||
EMC standards | Meet the FCC PART15J condition CLASS B |