Type and Specification | ||||
---|---|---|---|---|
Dimension | 30*30*52 | |||
Installation type | Unshielded | |||
All the output methods | DC type | NPN | NO | ATL-N10MN1 |
NC | ATL-N10MN2 | |||
NO+NC | ATL-N10MN3 | |||
PNP | NO | ATL-N10MP1 | ||
NC | ATL-N10MP2 | |||
NO+NC | ATL-N10MP3 | |||
Two-wire | NO | ATL-N10MD1 | ||
NC | ATL-N10MD2 | |||
AC type | Two-wire | NO | ATL-N10MA1 | |
NC | ATL-N10MA2 | |||
Detection range | 10mm±10% | |||
Setting distance | 0-11mm | |||
Delay distance | ≤10% detection range | |||
Detection object | Magnetic metal (the detection distance decreases when it is non-magnetic metal) |
|||
Standard detection object | SPCC iron 35*35*1mm | |||
Response frequency | DC: 0.8kHz, AC: 50Hz | |||
Supply voltage | DC type: DC 12-24V (6-36V), impulse (p-p) 10% below; AC type: AC 110-220V (90-250V) 50/60Hz |
|||
Withstand voltage | AC1000V 50/60Hz 1min between charging part and housing | |||
Voltage influence | Inside ±15% rated supply voltage range, at rated supply voltage value, inside ±10% detection distance |
|||
Consumption current | N/P type: ≤13mA, D type: ≤0.8mA, A type: ≤1.7mA | |||
Control output | N/P type: ≤200mA, D type: ≤200mA, A type: ≤200mA | |||
Loop protection | N/P/D type: reversal connection protection, surge absorption, load short-circuit protection, A type: surge absorption |
|||
Ambient temperature & humidity | Operation temperature/storage temperature: -30~65℃ (no freeze, no dew); Operation humidity/storage humidity: 35~95%RH |
|||
Temperature influence | Temperature range -30~65℃, at +23℃, ±15% detection distance; Temperature range -25~60℃, at +23℃, ±10% detection distance |
|||
Insulation impedance | ≥50MΩ (DC500 megameter) between charging part and housing | |||
Material | Housing: Nickel plated brass, Detection surface: ABS | |||
Protection class | IP67 | |||
Cable length | 2m |
ATL-N10MN1/N2
ATL-N10MN3
ATL-N10MP1/P2
ATL-N10MP3
ATL-N10MD1/D2
ATL-N10MA1/A2