Low price and high reliability
105℃ Output capacitor
AC input power suitable for the world
High efficiency and low operation temperature
Soft-start current can reduce the AC input impact effectively
With short-circuit and overload protection
100% full-load burn-in test
Installed with EMI filter, minimum wave
Model | |||||
---|---|---|---|---|---|
Specification | LPV-50-12 | LPV-100-24 | LPV-120-12 | LPV-150-24 | LPV-200-24 |
DC output voltage | 12V±5% | 24v±5% | 12v±5% | 12v±5% | 24v±5% |
Rated output current | 4.2A | 4.2A | 10A | 6.25A | 8.3A |
Output current range | 0-4.2A | 0-4.2A | 0-10A | 0-6.25A | 0-8.3A |
Wave and noise (Note: 3) | 100mVp-p | 150mVp-p | 50mVp-p | 100mVp-p | 100mVp-p |
Voltage accuracy | ±1% | ±1% | ±1% | ±1% | ±1% |
Inlet stability (Note: 4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stability (Note: 5) | ±1% | ±1% | ±1% | ±1% | ±1% |
DC Output power | 50W | 100W | 120W | 150W | 200W |
Efficiency | 0.82 | 0.86 | 0.8 | 0.8 | 0.8 |
AC input voltage range | 176~264VAC 50~60Hz; | ||||
Input current | 0.65A/230V | 1.2A/230V | 1.2A/230V | 1.6A/230V | 2.5A/230V |
AC Inrush current | Cole-start current 30A/115V 60A/230V | ||||
Leakage current | <0.5mA/240VAC | ||||
Overload proctection | 105%~150% Type: Cut off output Reset: auto recovery | ||||
Over-voltage protection | Short-circuit Over-load Over-heat | ||||
High-temperature protection | IP67 | ||||
Temperature coefficient | ±0.03%/℃(0~50℃) | ||||
Setup, rise, hold up time | 200ms, 100ms, 30ms | ||||
Vibration | 10~500Hz, 2G 10min,/1cycle, period for 60min, Each axes | ||||
Withstand voltage | Input and output internal: 1.5KVAC, Input and enclosure: 1.5KVAC, Output and enclosure: 0.5KVAC | ||||
Isolation resistance | Input and output internal: Input and enclosure, Output and enclosure: 500VDC/100MΩ | ||||
Working temperature and humidity | -30℃-65℃(Refer to output derating curve),20%~90%RH | ||||
Stoerall dimension | -40℃~+80℃,10%~95%RH | ||||
Overall dimension | 168x48x33mm | 163x68x42mm | 218x68x42mm | ||
Weight | 0.53kgs | 0.9kgs | 1.26kgs | ||
Safety standards | Meet UL 1012 requirement (Not apply for the mark) | ||||
EMC standards | Meet the FCC PART15J condition CLASS B |